Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584394

RESUMO

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Resultado do Tratamento , Cardioversão Elétrica/efeitos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
2.
Heart Rhythm ; 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493989

RESUMO

BACKGROUND: Atrial high-rate episodes (AHREs) are frequent in patients with cardiac implantable electronic devices. A decrease in device-detected P-wave amplitude may be an indicator of periods of increased risk of AHRE. OBJECTIVE: The objective of this study was to assess the association between P-wave amplitude and AHRE incidence. METHODS: Remote monitoring data from 2579 patients with no history of atrial fibrillation (23% pacemakers and 77% implantable cardioverter-defibrillators, of which 40% provided cardiac resynchronization therapy) were used to calculate the mean P-wave amplitude during 1 month after implantation. The association with AHRE incidence according to 4 strata of daily burden duration (≥15 minutes, ≥6 hours, ≥24 hours, ≥7 days) was investigated by adjusting the hazard ratio with the CHA2DS2-VASc score. RESULTS: The adjusted hazard ratio for 1-mV lower mean P-wave amplitude during the first month increased from 1.10 (95% confidence interval [CI], 1.05-1.15; P < .001) to 1.18 (CI, 1.09-1.28; P < .001) with AHRE duration strata from ≥15 minutes to ≥7 days independent of the CHA2DS2-VASc score. Of 871 patients with AHREs, those with 1-month P-wave amplitude <2.45 mV had an adjusted hazard ratio of 1.51 (CI, 1.19-1.91; P = .001) for progression of AHREs from ≥15 minutes to ≥7 days compared with those with 1-month P-wave amplitude ≥2.45 mV. Device-detected P-wave amplitudes decreased linearly during the 1 year before the first AHRE by 7.3% (CI, 5.1%-9.5%; P < .001 vs patients without AHRE). CONCLUSION: Device-detected P-wave amplitudes <2.45 mV were associated with an increased risk of AHRE onset and progression to persistent forms of AHRE independent of the patient's risk profile.

3.
Heart Rhythm ; 21(4): 410-418, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38246594

RESUMO

BACKGROUND: Outcome comparisons among subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients with nonischemic cardiomyopathies are scarce. OBJECTIVE: The aim of this study was to evaluate differences in device-related outcomes among S-ICD recipients with different structural substrates. METHODS: Patients enrolled in the i-SUSI (International SUbcutaneouS Implantable cardioverter defibrillator registry) project were grouped according to the underlying substrate (ischemic vs nonischemic) and subgrouped into dilated cardiomyopathy, hypertrophic cardiomyopathy, Brugada syndrome (BrS), arrhythmogenic right ventricular cardiomyopathy (ARVC). The main outcome of our study was to compare the rates of appropriate and inappropriate shocks and device-related complications. RESULTS: Among 1698 patients, the most common underlying substrate was ischemic (31.7%), followed by dilated cardiomyopathy (20.5%), BrS (10.8%), hypertrophic cardiomyopathy (8.5%), and ARVC (4.4%). S-ICD for primary prevention was more common in the nonischemic cohort (70.9% vs 65.4%; P = .037). Over a median (interquartile range) follow-up of 26.5 (12.6-42.8) months, no differences were observed in appropriate shocks between ischemic and nonischemic patients (4.8%/y vs 3.9%/y; log-rank, P = .282). ARVC (9.0%/y; hazard ratio [HR] 2.492; P = .001) and BrS (1.8%/y; HR 0.396; P = .008) constituted the groups with the highest and lowest rates of appropriate shocks, respectively. Device-related complications did not differ between groups (ischemic: 6.4%/y vs nonischemic: 6.1%/y; log-rank, P = .666), nor among underlying substrates (log-rank, P = .089). Nonischemic patients experienced higher rates of inappropriate shocks than did ischemic S-ICD recipients (4.4%/y vs 3.0%/y; log-rank, P = .043), with patients with ARVC (9.9%/y; P = .001) having the highest risk, even after controlling for confounders (adjusted HR 2.243; confidence interval 1.338-4.267; P = .002). CONCLUSION: Most S-ICD recipients were primary prevention nonischemic cardiomyopathy patients. Among those, patients with ARVC tend to receive the most frequent appropriate and inappropriate shocks and patients with BrS the least frequent appropriate shocks.


Assuntos
Displasia Arritmogênica Ventricular Direita , Cardiomiopatias , Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/terapia , Sistema de Registros , Resultado do Tratamento
4.
Int J Cardiol ; 400: 131807, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38272130

RESUMO

BACKGROUND: Left ventricular assist devices (LVADs) are an increasingly used strategy for the management of patients with advanced heart failure (HF). Subcutaneous implantable cardioverter defibrillator (S-ICD) might be a viable alternative to conventional ICDs with a lower risk of short- and long-term of device-related complications and infections.The aim of this multicenter study was to evaluate the outcomes and management of S-ICD recipients who underwent LVAD implantation. METHODS: The study population included patients with a preexisting S-ICD who underwent LVAD implantation for advanced HF despite optimal medical therapy. RESULTS: The study population included 30 patients (25 male; median age 45 [38-52] years).The HeartMate III was the most common LVAD type. Median follow-up in the setting of concomitant use of S-ICDs and LVADs was 7 months (1-20).There were no reports of inability to interrogate S-ICD systems in this population. Electromagnetic interference (EMI) occurred in 21 (70%) patients. The primary sensing vector was the one most significantly involved in determining EMI. Twenty-seven patients (90%) remained eligible for S-ICD implantation with at least one optimal sensing vector. The remaining 3 patients (10%) were ineligible for S-ICD after attempts of reprogramming of sensing vectors. Six patients (20%) experienced inappropriate shocks (IS) due to EMI. Six patients (20%) experienced appropriate shocks. No S-ICD extraction because of need for antitachycardia pacing, ineffective therapy or infection was reported. CONCLUSIONS: Concomitant use of LVAD and S-ICD is feasible in most patients. However, the potential risk of EMI oversensing, IS and undersensing in the post-operative period following LVAD implantation should be considered. Careful screening for EMI should be performed in all sensing vectors after LVAD implantation.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Marca-Passo Artificial , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Coração Auxiliar/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento
5.
Clin Kidney J ; 16(12): 2683-2692, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38046009

RESUMO

Background: The prevalence of atrial fibrillation (AF) in end stage kidney disease (ESKD) patients undergoing dialysis is high, however, the high risk of bleeding often hampers with a correct anticoagulation in ESKD patients with AF, despite high thromboembolic risk. Left atrial appendage (LAA) occlusion is a anticoagulation (OAT) for thromboembolism prevention in AF populations with high hemorrhagic risk. Methods and Results: The purpose of the study was to evaluate the efficacy and safety of LAA occlusion in a cohort of dialysis patients undergoing the procedure (LAA occlusion cohort, n = 106), in comparison with two other ESKD cohorts, one taking warfarin (Warfarin cohort, n = 114) and the other without anticoagulation therapy (No-OAT cohort, n = 148). After a median follow-up of 4 years, a Cox regression model, adjusted for possible confounding factors, showed that the hazard ratios (HRs) of thromboembolic events in the LAA occlusion cohort were 0.19 (95%CI 0.04-0.96; p = 0.045) and 0.16 (95%CI 0.04-0.66; p = 0.011) as compared with Warfarin and No-OAT cohorts, respectively. The HR of bleeding in the LAA occlusion cohort was 0.37 (95%CI 0.16-0.83; p = 0.017) compared to Warfarin cohort, while there were no significant differences between the LAA occlusion and the No-OAT cohort (HR 0.51; 95%CI 0.23-1.12; p = 0.094). Adjusted Cox regression models showed lower mortality in patients undergoing LAA occlusion as compared with both the Warfarin cohort (HR 0.60; 95%CI 0.38-0.94; p = 0.027) and no-OAT cohort (HR 0.52; 95%CI 0.34-0.78; p = 0.002). Thromboembolic events in the LAA occlusion cohort were lower than expected according to the CHA2DS2VASc score (1.7 [95%CI 0.3-3.0] vs 6.7 events per 100 person/years, p < 0.001). Conclusion: In ESKD patients with AF, LAA occlusion is safe and effective and is associated with reduced mortality compared with OAT or no therapy.

6.
J Cardiovasc Electrophysiol ; 34(12): 2443-2451, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37767727

RESUMO

INTRODUCTION: Regardless of the catheter ablation (CA) for atrial fibrillation (AF) strategy, the role of early recurrences during the blanking period (BP) is still unclear. Our aim was to evaluate atrial tachyarrhythmias (ATAs) recurrences during the BP after CA with the laser-balloon (LB) technique. METHODS: Consecutive patients undergoing LBCA were enrolled. Primary outcome of the study was the overall crude ATA recurrence rate during the BP. ATA recurrences after the BP and in-hospital readmissions during the BP were deemed secondary outcomes. RESULTS: Two hundred and twenty-four patients underwent CA with the LB. Median age was 63.0 (55.5-69.5) years and 74.1% were males. 28.6% were persistent AF patients, and 34.8% of patients were followed up with a loop recorder. 15.6% of patients experienced at least an ATA recurrence during the BP. Male sex, chronic heart failure, persistent AF, and recurrences during the BP were found to be associated with long-term ATA recurrences. Recurrences during the BP remained associated with the outcome of interest at multivariate analysis (hazard ratio [HR] = 12.393, 95% confidence interval [95% CI] = 3.699-41.865, p < .001). An association over time was found between early and late recurrences, with 73.7%, 45.5%, and 10.8% of patients presenting with recurrences at 1-, 2-, and 3-month follow-up being free from recurrences after the BP, respectively. 8.0% of patients were readmitted during the BP: 4.5% for AF electrical cardioversion, and 1.8% for CA of other atrial arrhythmias; no redo CA was performed. CONCLUSION: After adjusting for confounders, ATA recurrences during the BP represent the most significant predictor of ATA recurrences after the BP, regardless of AF pattern.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Fatores de Tempo , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva , Veias Pulmonares/cirurgia , Lasers
7.
Artigo em Inglês | MEDLINE | ID: mdl-37697222

RESUMO

BACKGROUND: The aims of this analysis were: to evaluate the impact of timing of ablation on the rate of atrial arrhythmias recurrence, verify if the timing of ablation impact differently in patients with paroxysmal and persistent AF. METHODS: Three thousand two hundred and five patients (60.5 ± 10 years, female 28.4%%, 78.8%% paroxysmal AF) were included in the analysis. All patients underwent only cryoballoon (CB) pulmonary vein (PV) isolation during the index procedure. RESULTS: The mean procedure time was 102.8 ± 50 min, with a mean fluoroscopy time of 26.3 ± 49 min. Acute PV isolation was achieved in 11760/11793 (99.7%) PVs. A total of 91 (2.8%) patients experienced a procedure-related complication. During the observation period 913/3205 (28.5%) patients had at least one atrial arrhythmias episode: 28% of patients with paroxysmal AF vs 33% of patients with persistent AF. In multivariate analysis, persistent AF together with time from symptomatic AF diagnosis to ablation, female sex, and ablation time showed to be significant predictors for AF recurrence. In particular, months from first symptomatic AF episode > 18 months was a significant predictor of AF recurrence (HR = 1.23, 95% CI = 1.03-1.46, p = 0.020). In patients with paroxysmal AF, the multivariate analysis confirmed that months from first symptomatic AF episode > 18 month was an independent predictor of AF recurrence together with age > 62 years and female sex. In patients with persistent AF, the time from persistent AF showed to be significant predictor for AF recurrence. CONCLUSIONS: In this multicenter analysis, time from first symptomatic AF episode > 18 months was a significant predictor of AF recurrence after CB PV isolation.

8.
Heart Rhythm ; 20(10): 1429-1435, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37481220

RESUMO

BACKGROUND: The impact of sex in clinical and procedural outcomes in leadless pacemaker (LPM) patients has not yet been investigated. OBJECTIVE: The purpose of this study was to investigate sex-related differences in patients undergoing LPM implantation. METHODS: Consecutive patients enrolled in the i-LEAPER registry were analyzed. Comparisons between sexes were performed within the overall cohort using an adjusted analysis with 1:1 propensity matching for age and comorbidities. The primary outcome was the comparison of major complication rates. Sex-related differences regarding electrical performance and all-cause mortality during follow-up were deemed secondary outcomes. RESULTS: In the overall population (n = 1179 patients; median age 80 years), 64.3% were men. After propensity matching, 738 patients with no significant baseline differences among groups were identified. During median follow-up of 25 [interquartile range 24-39] months, female sex was not associated with LPM-related major complications (hazard ratio [HR] 2.03; 95% confidence interval [CI] 0.70-5.84; P = .190) or all-cause mortality (HR 0.98; 95% CI 0.40-2.42; P = .960). LPM electrical performance results were comparable between groups, except for a higher pacing impedance in women at implant and during follow-up (24 months: 670 [550-800] Ω vs 616 [530-770] Ω; P = .014) that remained within normal limits. CONCLUSION: In a real-world setting, we found differences in sex-related referral patterns for LPM implantation with an underrepresentation of women, although major complication rate and LPM performance were comparable between sexes. Female patients showed higher impedance values, which had no impact on overall device performance. Electrical parameters remained within normal limits in both groups during the entire follow-up.

9.
Heart Rhythm ; 20(2): 233-240, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-37283031

RESUMO

BACKGROUND: Elevated resting heart rate is a risk factor for cardiovascular events. OBJECTIVE: The purpose of this study was to investigate the clinical significance of nocturnal heart rate (nHR) and 24-hour mean heart rate (24h-HR) obtained by continuous remote monitoring (RM) of implantable devices. METHODS: We analyzed daily-sampled trends of nHR, 24h-HR, and physical activity in patients on ß-blocker therapy for chronic heart failure and with implantable cardioverter-defibrillators or cardiac resynchronization therapy defibrillators (CRT-Ds). Patients were grouped by average nHR and 24h-HR quartile during follow-up to estimate the respective incidence of nonarrhythmic death and device-treated ventricular tachycardia/fibrillation (VT/VF). RESULTS: The study cohort included 1330 patients (median age 69 years [interquartile range 61-77 years]; 41% [n = 550] with CRT-D; median follow-up 25 months [interquartile range 13-42 months]). Compared with patients in the lowest nHR quartile (≤57 beats/min) group, patients in the highest quartile group (>65 beats/min) had an increased risk of nonarrhythmic death (adjusted hazard ratio [AHR] 2.25; 95% confidence interval [CI] 1.13-4.50; P = .021) and VT/VF (AHR 1.98; 95% CI 1.40-2.79; P < .001) and were characterized by the lowest level of physical activity (P ≤ .0004 vs every other nHR quartiles). The highest 24h-HR quartile group (>75 beats/min) showed an increased risk of VT/VF (AHR 2.13; 95% CI 1.52-2.99; P < .001) and a weaker though significant association with nonarrhythmic mortality (AHR 1.80; 95% CI 1.00-3.22; P = .05) as compared with the lowest 24h-HR quartile group (≤65 beats/min). CONCLUSION: In remotely monitored patients with implantable cardioverter-defibrillator/CRT-D on ß-blocker therapy for heart failure, elevated heart rates (nHR >65 beats/min and 24h-HR >75 beats/min) were associated with increased mortality and VT/VF risk. nHR showed a stronger association than 24h-HR with worst prognosis and lowest physical activity.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Disfunção Ventricular Esquerda , Humanos , Pessoa de Meia-Idade , Idoso , Frequência Cardíaca , Prognóstico , Volume Sistólico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Arritmias Cardíacas/terapia , Fatores de Risco , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Disfunção Ventricular Esquerda/complicações
10.
J Cardiovasc Electrophysiol ; 34(4): 947-956, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36709469

RESUMO

INTRODUCTION: Thoracic impedance (TI) drops measured by implantable cardioverter-defibrillators (ICDs) have been reported to correlate with ventricular tachycardia/fibrillation (VT/VF). The aim of our study was to assess the temporal association of decreasing TI trends with VT/VF episodes through a longitudinal analysis of daily remote monitoring data from ICDs and cardiac resynchronization therapy defibrillators (CRT-Ds). METHODS AND RESULTS: Retrospective data from 2384 patients were randomized 1:1 into a derivation or validation cohort. The TI decrease rate was defined as the percentage of rolling weeks with a continuously decreasing TI trend. The derivation cohort was used to determine a TI decrease rate threshold for a ≥99% specificity of arrhythmia prediction. The associated risk of VT/VF episodes was estimated in the validation cohort by dividing the available follow-up into 60-day assessment intervals. Analyses were performed separately for 1354 ICD and 1030 CRT-D patients. During a median follow-up of 2.0 years, 727 patients (30.4%) experienced 3298 confirmed VT/VF episodes. In the ICD group, a TI decrease rate of >60% was associated with a higher risk of VT/VF episode in a 60-day assessment interval (stratified hazard ratio, 1.42; 95% confidence interval (CI), 1.05-1.92; p = .023). The TI decrease preceded (40.8%) or followed (59.2%) the VT/VF episodes. In the CRT-D group, no association between TI decrease and VT/VF episodes was observed (p = .84). CONCLUSION: In our longitudinal analysis, TI decrease was associated with VT/VF episodes only in ICD patients. Preventive interventions may be difficult since episodes can occur before or after TI decrease.


Assuntos
Arritmias Cardíacas , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/terapia , Impedância Elétrica , Estudos Retrospectivos , Fibrilação Ventricular , Desfibriladores Implantáveis
11.
Int J Cardiol ; 371: 197-203, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36115442

RESUMO

BACKGROUND: Age-related differences on leadless pacemaker (LP) are poorly described. Aim of this study was to compare clinical indications, periprocedural and mid-term device-associated outcomes in a large real-world cohort of LP patients, stratified by age at implantation. METHODS: Two cohorts of younger and older patients (≤50 and > 50 years old) were retrieved from the iLEAPER registry. The primary outcome was to compare the underlying indication why a LP was preferred over a transvenous PM across the two cohorts. Rates of peri-procedural and mid-term follow-up major complications as well as LP electrical performance were deemed secondary outcomes. RESULTS: 1154 patients were enrolled, with younger patients representing 6.2% of the entire cohort. Infective and vascular concerns were the most frequent characteristics that led to a LP implantation in the older cohort (45.8% vs 67.7%, p < 0.001; 4.2% vs 16.4%, p = 0.006), while patient preference was the leading cause to choose a LP in the younger (47.2% vs 5.6%, p < 0.001). Median overall procedural (52 [40-70] vs 50 [40-65] mins) and fluoroscopy time were similar in both groups. 4.3% of patients experienced periprocedural complications, without differences among groups. Threshold values were higher in the younger, both at discharge and at last follow-up (0.63 [0.5-0.9] vs 0.5 [0.38-0-7] V, p = 0.004). CONCLUSION: When considering LP indications, patient preference was more common in younger, while infective and vascular concerns were more frequent in the older cohort. Rates of device-related complications did not differ significantly. Younger patients tended to have a slightly higher pacing threshold at mid-term follow-up.


Assuntos
Marca-Passo Artificial , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento , Desenho de Equipamento , Marca-Passo Artificial/efeitos adversos , Fatores de Tempo , Estimulação Cardíaca Artificial/efeitos adversos
12.
Int J Cardiol ; 373: 57-63, 2023 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-36460209

RESUMO

BACKGROUND: Reliable post-approval surveillance of implantable cardioverter-defibrillator (ICD) lead performance remains a challenge. In the past, two ICD leads were recalled due to a high frequency of failures. In this meta-analysis, we sought to provide a combined estimate of failure-free rate for ICD leads by reconstructing individual patient data from published Kaplan-Meier (KM) curves and to investigate whether estimates could be influenced by the characteristics of the study. METHODS: Observational studies assessing failure-free estimates of transvenous ICD leads with KM method, were identified through a systematic search up to November 2021. RESULTS: Forty-four studies were eligible that included 41,870 (63.1%) non-recalled leads and 24,493 (36.9%) recalled leads. The 8-year cumulative failure-free rate was 94.1% (CI, 93.6% - 94.6%) for contemporary non-recalled leads and 81.2% (80.3% - 82.0%) for recalled leads (hazard ratio [HR], 3.15 [2.85-3.47], p < 0.001). Failure-free rate was lower in single-center studies in both the non-recalled (HR, 0.28 [0.15-0.51], p < 0.001) and recalled (HR, 0.54 [0.33-0.88], p = 0.014) group compared with multicenter studies. Similarly, estimates were significantly lower in small (i.e. extracted KM curve with <312 leads) versus large studies (HR non-recalled group, 0.54 [CI, 0.33-0.89], p = 0.015; HR recalled group, 0.62 [CI, 0.43-0.89], p = 0.009). CONCLUSIONS: In this meta-analysis including >66,000 leads, we provide pooled survival curves that may play a role in generating evidence-based standards for assessing clinically acceptable failure rates for ICD leads. Lead performance was underestimated with single-center and small-sized studies; multicenter studies remain the main tool to reliably conduct post-market surveillance of ICD leads.


Assuntos
Desfibriladores Implantáveis , Humanos , Estudos Retrospectivos , Modelos de Riscos Proporcionais , Estudos Observacionais como Assunto
13.
Heart Rhythm ; 20(3): 395-404, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36496135

RESUMO

BACKGROUND: Limited data on the real-world safety and efficacy of leadless pacemakers (LPMs) post-transvenous lead extraction (TLE) are available. OBJECTIVE: The purpose of this study was to assess the long-term safety and effectiveness of LPMs following TLE in comparison with LPMs de novo implantation. METHODS: Consecutive patients who underwent LPM implantation in 12 European centers joining the International LEAdless PacemakEr Registry were enrolled. The primary end point was the comparison of LPM-related complication rate at implantation and during follow-up (FU) between groups. Differences in electrical performance were deemed secondary outcomes. RESULTS: Of the 1179 patients enrolled, 15.6% underwent a previous TLE. During a median FU of 33 (interquartile range 24-47) months, LPM-related major complications and all-cause mortality did not differ between groups (TLE group: 1.6% and 5.4% vs de novo group: 2.2% and 7.8%; P = .785 and P = .288, respectively). Pacing threshold (PT) was higher in the TLE group at implantation and during FU, with very high PT (>2 V@0.24 ms) patients being more represented than in the de novo implantation group (5.4% vs 1.6 %; P = .004). When the LPM was deployed at a different right ventricular (RV) location than the one where the previous transvenous RV lead was extracted, a lower proportion of high PT (>1-2 V@0.24 ms) patients at implantation, 1-month FU, and 12-month FU (5.9% vs 18.2%, P = .012; 3.4% vs 12.9%, P = .026; and 4.3% vs 14.5%, P = .037, respectively) was found. CONCLUSION: LPMs showed a satisfactory safety and efficacy profile after TLE. Better electrical parameters were obtained when LPMs were implanted at a different RV location than the one where the previous transvenous RV lead was extracted.


Assuntos
Marca-Passo Artificial , Humanos , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Estimulação Cardíaca Artificial/efeitos adversos , Sistema de Registros , Desenho de Equipamento
14.
Clin Cardiol ; 46(2): 142-150, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36448243

RESUMO

BACKGROUND: Atrial fibrillation (AF) is an uncommon arrhythmia in young adults without structural heart disease, and cryoballoon pulmonary vein isolation (CB-PVI) is an important therapeutic strategy for rhythm control in patients with drug-refractory AF. The aim of this analysis was to evaluate efficacy and safety of CB-PVI in a large cohort of young patients in comparison with middle-aged adults in a real-world setting. METHODS: From 2012 to 2020, a total of 3033 patients with AF underwent CB-PVI and were followed prospectively in the framework of the 1STOP Clinical Service project, involving 34 Italian centers. Out of 3033 total 1STOP project subjects, a subgroup of 1318 patients were defined which included a YOUNG group (age ≤ 45 years; n = 368) and a MIDDLE-AGED group (age 60-65 years; n = 950). RESULTS: The acute success rate of PVI did not differ between the two cohorts (99.9 ± 1.3% vs. 99.8 ± 3.2%, p = 0.415). There was no difference in procedural characteristics, and periprocedural complication rates were similar among the two cohort (1.9% vs. 2.3%, p = 0.646). The 12-month freedom from AF recurrence was 88.9% (95% confidence interval [CI]: 84.7-92.0) in the YOUNG cohort and 85.6% (95% CI: 82.9-88.0) in the MIDDLE-AGED group. At 36-month follow-up, freedom from AF recurrence was 72.4% (65.5%-78.2%) and 71.8% (67.7%-75.6%), respectively with no significant difference among groups (p = 0.550). CONCLUSION: CB-PVI had similar efficacy and safety in YOUNG and MIDDLE-AGED patients. Younger age did not affect acute procedural results, complication rate, or AF recurrence after a single procedure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Cardiopatias , Veias Pulmonares , Pessoa de Meia-Idade , Adulto Jovem , Humanos , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Recidiva , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
15.
J Interv Card Electrophysiol ; 66(5): 1193-1200, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36417124

RESUMO

BACKGROUND: Pulmonary vein isolation by cryoablation (PVI-C) is a standard therapy for the treatment of atrial fibrillation (AF). The CHA2DS2-VASc score is a well-established predictor of AF-related stroke. Whether the CHA2DS2-VASc score can also be useful in predicting the long-term clinical outcomes following PVI-C is still unsettled. The aim of this analysis was to evaluate the role of the CHA2DS2-VASc score in predicting AF recurrence after PVI-C. METHODS: Patients with symptomatic AF underwent an index PVI-C. Data were collected prospectively in the framework of the 1STOP ClinicalService project. Patients were categorized into two groups: low risk (LR) and high risk (HR) based on CHA2DS2-VASc score (0-1 and ≥ 2, respectively). RESULTS: Out of 3313 patients, 1910 (57.6%) had a CHA2DS2-VASc score between 0 and 1, while 1403 (42.3%) had CHA2DS2-VASc > = 2. Patient characteristics were significantly different between the two cohorts, including age, sex, BMI, paroxysmal AF, history of stroke, diabetes, and ischemic cardiomyopathy. On the contrary, procedural times and acute complications were comparable. The 36-month freedom from AF after a single procedure was 72.5% (95% CI: 69.8-75.0) in the LR group and 65.9% (95% CI: 62.3-69.2) in the HR score group (HR: 1.26, 95% CI: 1.08-1.47, p = 0.001). After multivariate analysis, higher CHA2DS2-VASc score was still a significant predictor of the risk of AF recurrence (HR: 1.33; 1.10-1.60, p = 0.003). CONCLUSIONS: PVI-C is highly effective in the treatment of AF over the long term. A CHA2DS2-VASc score ≥ 2 is an independent predictor of AF recurrence during the follow-up and should be considered during the clinical management after the index procedure.


Assuntos
Fibrilação Atrial , Criocirurgia , Veias Pulmonares , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Veias Pulmonares/cirurgia , Fatores de Risco , Criocirurgia/métodos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Medição de Risco/métodos , Recidiva
16.
J Cardiovasc Electrophysiol ; 34(3): 728-737, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36477909

RESUMO

INTRODUCTION: Lead dwell time >10 years is a recognized predictor for transvenous lead extraction (TLE) failure and complications. Data on the efficacy and safety of TLE using the bidirectional rotational mechanical sheaths in patients with very old leads are lacking. In this multicenter study, we reported the outcomes of transvenous rotational mechanical lead extraction in patients with leads implanted for ≥10 years. METHODS: A total of 441 leads (median: 159 months [135-197]; range: 120-487) in 189 consecutive patients were removed with the Evolution RL sheaths (Cook Medical, Bloomingtom, IN, USA) and mechanical ancillary tools supporting the procedures. RESULTS: The main indication for TLE was infection in 74% of cases. Complete procedural success rate, clinical success rate, per lead were 94.8% and 98.2%, respectively. Failure of lead extraction was seen in 1.8% of leads. The additional use of a snare via the femoral approach was required in 9% of patients. Lead dwell time was the only predictor of incomplete led removal (odds ratio: 1.009; 95% confidence interval [CI]: 1.003-1.014; p = .002). Four major complication (2%) were encountered. During a mean time follow-up of 31 ± 27 months, 21 patients (11%) died. No procedure-related mortality occurred. Predictors of mortality included severe left ventricular systolic dysfunction (hazard ratio [HR]: 8.06; 95% CI: 2.99-21.73; p = .001), TLE for infection (HR: 8.0; 95% CI: 1.04-62.5; p = .045), diabetes (HR: 3.7; 95% CI: 1.48-9.5; p = .005), and previous systemic infection (HR: 3.1; 95% CI: 1.17-8.24; p = .022). Incomplete lead removal or failure lead extraction did not impact on survival during follow-up. CONCLUSION: Our findings demonstrated that the use of bidirectional rotational TLE mechanical sheaths combined with different mechanical tools and femoral approach allows reasonable success and safety in patients with very old leads at experienced specialized centers.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Remoção de Dispositivo/métodos , Eletrodos Implantados , Estudos Retrospectivos , Resultado do Tratamento
17.
JACC Clin Electrophysiol ; 8(12): 1553-1562, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36543505

RESUMO

BACKGROUND: Causes of sex differences in incidence of sustained ventricular arrhythmias (SVAs) are poorly understood. OBJECTIVES: This study aims to investigate sex-specific risk of SVAs and device therapies by balancing sex groups in relation to several baseline characteristics with the propensity score (PS). METHODS: We used a large remote monitoring dataset from implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds). Study endpoints were time to the first appropriate SVA, time to the first device therapy for SVA, and time to the first ICD shock. Results were compared between females and a PS-matched male subgroup. RESULTS: In a cohort of 2,532 patients with an ICD or CRT-D (median age, 70 years), 488 patients (19.3%) were women. After selecting 488 men PS-matched for 19 variables relative to baseline demographics, implant indications, principal comorbidities, and concomitant therapy, yet the SVA rate at the 2.1-year median follow-up was significantly lower in women than in man (adjusted HR: 0.65; 95% CI: 0.51-0.81; P < 0.001). Women also showed a reduced risk of any device therapy (HR: 0.59; 95% CI: 0.45-0.76; P < 0.001) and shocks (HR: 0.66; 95% CI: 0.47-0.94; P = 0.021). Differences in sex-specific SVA risk profile were not confirmed in CRT-D patients (HR: 0.78; 95% CI: 0.55-1.09; P = 0.14) nor in those with an ejection fraction <30% (HR: 0.80; 95% CI: 0.52-1.23; P = 0.31). CONCLUSIONS: After matching demographics, indications, principal comorbidities, and concomitant therapy, women still exhibited a lower SVA risk profile than men, except in the subgroups of CRT-D or/and ejection fraction <30%.


Assuntos
Desfibriladores Implantáveis , Humanos , Masculino , Feminino , Idoso , Desfibriladores Implantáveis/efeitos adversos , Pontuação de Propensão , Resultado do Tratamento , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Cardioversão Elétrica
18.
J Cardiovasc Dev Dis ; 9(5)2022 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-35621837

RESUMO

The aim of this research was to evaluate if patients with chronic kidney disease (CKD) and mild or mild to moderate depression of renal function have an increased risk of atrial fibrillation (AF) recurrences after cryoballoon (CB) ablation. We performed a retrospective analysis of AF patients undergoing pulmonary vein isolation (PVI) by CB. The cohort was divided according to the KDIGO CKD-EPI classification into a (1) normal, (2) mildly decreased, or (3) mild to moderate reduction in estimated glomerular filtration rate (eGFR). Freedom from AF recurrences was the primary endpoint. A total of 1971 patients were included (60 ± 10 years, 29.0% females, 73.6% paroxysmal AF) in the study. Acute success and complication rates were 99.2% and 3.7%, respectively, with no significant differences among the three groups. After a follow-up of 24 months, AF recurrences were higher in the mildly and mild to moderate CKD groups compared to the normal kidney function group (23.4% vs. 28.3% vs. 33.5%, p < 0.05). Mild to moderate CKD was an independent predictor of AF recurrences after the blanking period (hazard ratio:1.38, 95% CI 1.02−1.86, p = 0.037). In conclusion, a multicenter analysis of AF patients treated with cryoablation revealed mild to moderate reductions in renal functions were associated with a higher risk of AF recurrences. Conversely, the procedural success and complication rates were similar in patients with normal, mildly reduced, or mild to moderate reduction in eGFR.

19.
Pacing Clin Electrophysiol ; 45(8): 968-974, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35417055

RESUMO

BACKGROUND: It has been observed that the fourth-generation cryoballoon (CB4) ablation catheter increased the rate of acute real-time recordings of pulmonary vein isolation (PVI) during the ablation for the treatment of atrial fibrillation (AF). The aim of this analysis was to compare the long-term outcome results between patients treated with the CB4 and second-generation cryoballoon (CB2). METHODS: In total, 492 patients suffering from AF, underwent PVI ablation with either the CB2 or CB4 catheter within this examination of the 1STOP real-world Italian project and were included in the analysis. Specifically, 246 consecutive patients treated by CB4 were compared to 246 propensity-matched control patients who underwent PVI using CB2. RESULTS: When comparing the patient cohorts treated with CB2 versus CB4, acute success rate (99.6 ± 4.7% vs. 99.7 ± 3.6%, p = .949) and peri-procedural complications (3.7% vs.1.2%, p = .080) were similar in both groups, respectively. However, procedure time (100 vs.75 min, p < .001) and fluoroscopy duration (21 vs.17 min, p < .001) were all significantly lower in the CB4 treated patient cohort. At the 12-month follow-up, the freedom from AF recurrence after a 90-day blanking period was significant higher in the CB4 as compared with the CB2 group (93.3% vs.81.3%, p < .001). CONCLUSIONS: In summary, usage of the CB4 ablation catheter increased the rate of acute PVI recording capability and resulted in a higher rate of long-term PVI success, as demonstrated by the reduced rate of AF recurrence in comparison to the CB2 cohort at the 12-month follow-up period.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Ablação por Cateter/métodos , Cateteres , Criocirurgia/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
20.
Hellenic J Cardiol ; 65: 1-7, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35331905

RESUMO

OBJECTIVE: Cryoballoon (CB) and laser-balloon (LB) catheter ablation (CA) has been demonstrated to achieve durable and effective pulmonary vein isolation (PVI). Only one head-to-head comparison with an intermittent rhythm monitor strategy is currently available. The aim of this study was to compare acute and long-term outcomes of CB and LB atrial fibrillation ablation procedures, by using a continuous rhythm monitoring strategy. METHODS: This was a prospective two-arm nonrandomized propensity-matched observational trial that compared the outcomes of atrial fibrillation (AF) ablation using LB and CB techniques. To evaluate AF recurrences, an implantable cardiac monitor (ICM) was implanted before hospital discharge to detect atrial tachyarrhythmia (ATA) recurrences. RESULTS: A total of 110 propensity-matched patients undergoing AF ablation with an LB (n = 55) or with a CB system (n = 55) were enrolled (paroxysmal AF 57.3%). Procedural time (LB: 87 [73-104] vs. CB 90 [70-130] min; p = 0.264) and fluoroscopy time did not differ. No differences in ATA recurrences were observed at 12 months (LB-30.9% vs. CB-29.1% and LB-45.5% vs. CB-38.2%; log-rank 0.539). As for AF burden, the 12-month median was 0 [0-1] vs. 0 [0-3]% (p = 0.127) in the LB and CB groups, respectively. When considering only PeAF patients, the median 12-month ATA burden was 26 [18.5-40.5] vs. 29 [26-35]% (p = 0.919) for the LB and CB patients, respectively. CONCLUSION: In a propensity-matched cohort undergoing AF ablation, arrhythmia outcomes assessed by continuous rhythm monitoring did not differ between LB and CB, with an overall low ATA burden. The only predictor of recurrences was persistent AF. There was no difference in procedure or fluoroscopy time.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Humanos , Lasers , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...